Operator Controls
- Vacuum on/off by RF 433Mhz remote control
- Heaters on/off by RF 433Mhz remote control (heated version only)
- On/off functions have a manual override switch and can be switched on/off by a remote computer via an Optically Isolated Host I/O interface (heated version only)
- Clearly visible, 360° around controller console, High Intensity status LEDs (heated version only)
Electrical
- Controller Supply Voltage 400+0+Ground [50/60Hz] V(AC)
- To be fused with external fuses of 3x32 Amp
- Max. Power Load 6.8 kW (heated version only)
- Console power cable of 6 meters with wander plugs included
- Pre-wired pump
Operating Conditions
- Temperature 18 – 35 ˚C
- Relative Humidity 30-90 %
- Noise 70 dB(A) ****
**** with included silencer and depending on covering of tray with media and physical mounting/location of vacuum pump